Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
Search Results "Handrail Continuity"
Commonly Searched Documents
-
Ground Surfaces: ADA Standard Section 1008.2.6
- Schumacher Elevator Company: 75th Anniversary Celebration Video
-
§ 38.97(b)
(b) Where provided, handrails or stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with disabilities...
-
§ 38.115(b)
(b) Where provided, handrails and stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with disabilities...
-
11B-1007.2 Accessible routes
Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with Section 11B-505....
-
11B-1007.2 Accessible routes
Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with Section 11B-505....
-
Egress Stairs
The requirement for a minimum 48 inch width between handrails is specific to stairs adjacent to areas of rescue assistance and does not apply generally to stairs covered by 4.9....
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1003.2.13.2 Enclosed stairways
An enclosed stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area...
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
§ 38.155(b)
(b) Where provided within passenger compartments, handrails or stanchions shall be sufficient to permit safe on-board circulation, seating and standing assistance, and alighting by persons...
- Rebuilding Together Portland - Portland, OR
-
11B-1008.2.6 Ground surfaces
Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
Edge Protection
Edge Protection Where railings, guards, or handrails are provided, edge protection must be provided and extend a minimum of 2 inches above the ground or deck surface....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-405.9 Edge protection
Exceptions: Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with Section 11B-406.2.2....
-
1991 Standards v. 2010 Standards
The 1991 Standards, at sections 4.8.5, 4.9.4, and 4.26, and the 2010 Standards, at section 505, contain technical requirements for handrails....
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
1607.8 Loads on handrails, guards, grab bars shower seats, dressing room bench seats and seats
[See subsections ...]
-
M303.3.3 Ramped (Section-by-Section Analysis)
wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with technical requirements for running slope, cross slope, clear width, edge protection, and handrails...