Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
Search Results "Elevator"
Commonly Searched Documents
- 
    
  
  11B-411.4.7.2 Location
  
- 
    
  
  11B-407.4.8.2 Audible indicators
  Audible indicators shall comply with Section 11B-407.4.8.2. 
- 
    
  
  11B-409.4.4 Leveling
  Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions. 
- 
    
  
  11B-407.2.1.1 Height
  Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:... 
- 
    
  
  11B-411.2.1.3 Arrangement
  Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3. 
- 
    
  
  11B-411.2.1 Hall call consoles
  Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309. 
- 
    
  
  11B-411.2.1.4 Additional features
  Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4. 
- 
    
  
  Audible Tones/Bells or Verbal Annunciators
  ...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?... 
- 
    
  
  407.4.8.2.1 Signal Type
  EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz... 
- 
    
  
  407.4.8.2.1 Signal Type
  [ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with... 
- 
    
  
  407.4.8.2.1 Signal Type
  EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz... 
- 
    
  
  11B-409.4.6.1 Size
  Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension. 
- 
    
  
  409.4.6.1 Size
  Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. 
- 
    
  
  409.4.6.2 Location
  Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. 
- 
    
  
  409.4.6.1 Size
  Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. 
- 
    
  
  409.4.6.1 Size
  409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. 
- 
    
  
  11B-409.4.6.2 Location
  Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. 
- 
    
  
  11B-409.4.6.1 Size
  Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension. 
- 
    
  
  11B-409.4.6.1 Size
  Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension. 
- 
    
  
  11B-409.4.6.2 Location
  Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. 
- 
    
  
  1008.2.1 Ground Level and Elevated Play Components
  1008.2.1 Ground Level and Elevated Play Components.... 
- 
    
  
  11B-407.2.1.3 Clear floor or ground space
  The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users... 
- 
    
  
  4.1.6(3)(c)(iii)
  (iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible comply... 
- 
    
  
  1008.2.1 Ground Level and Elevated Play Components
  Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the... 