Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?...
Search Results "Compartment Door"
Commonly Searched Documents
- 
    
  
  D3. Door Hardware
  
- 
    
  
  11B-404.2.10 Door and gate surfaces
  Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door... 
- 
    
  
  11B-404.2.10 Door and gate surfaces
  Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door... 
- 
    
  
  11B-404.2.10 Door and gate surfaces
  Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door... 
- 
    
  
  11B-608.10 Soap dish
  Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat. 
- 
    
  
  4.21.1* General
  Accessible shower stalls shall comply with 4.21. 
- 
    
  
  4.17.4 Toe Clearances
  In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater... 
- 
    
  
  4.21 Shower Stalls
  [See subsections ...] 
- 
    
  
  A4.21 Shower Stalls
  [See subsections ...] 
- 
    
  
  4.17.4 TOE CLEARANCES
  In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater... 
- 
    
  
  4.21.1* GENERAL
  Accessible shower stalls shall comply with 4.21. For shower stalls in accessible dwelling units, see 4.34.5.5. 
- 
    
  
  A4.21 SHOWER STALLS
  [See subsections ...] 
- 
    
  
  Shower Stalls (ADAAG 4.21)
  Shower Stalls (ADAAG 4.21) Although ADAAG permits both transfer and a roll-in showers, roll-in showers were found in institutional facilities. As a result, design of shower stalls... 
- 
    
  
  11B-608.10 Soap dish
  11B-608.10 Soap dish. Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from... 
- 
    
  
  11B-608.10 Soap dish
  Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat. 
- 
    
  
  G. Door Hardware
  Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching... 
- 
    
  
  Closers
  Closers Automated door closing is addressed by the ANSI/BHMA standards.... 
- 
    
  
  A. Entry Doors
  Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs... 
- 
    
  
  407.3.6 Width
  The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted.... 
- 
    
  
  Door Opening Force [4.13.11]
  [See subsections ...] 
- 
    
  
  407.3.6 Width
  The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted.... 
- 
    
  
  11B-407.3.6 Width
  The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted.... 
- 
    
  
  11B-407.3.6 Width
  The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted.... 
- 
    
  