1132A.4 Level floor or landing. See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors...
Search Results "Clearance Around Base"
Commonly Searched Documents
-
1132A.4 Level floor or landing
-
8. Gap
8. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
11. Gap
11. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
H. Drop-off Area Height
H. Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area? [ADA Stds. 4.6.5] Yes __ No __ N/A __ Comments:...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
4.3.5 HEAD ROOM
Accessible routes shall comply with 4.4.2.
-
6.3(2)
(2) Each bedroom shall have adequate space to provide a maneuvering space that complies with 4.2.3. In rooms with 2 beds, it is preferable that this space be located between beds.
-
4.3.5 Head Room
Accessible routes shall comply with 4.4.2.
-
6.3(1)
(1) Each bedroom shall have a turning space that complies with 4.2.3, and preferably that is located near the entrance.
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior...
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
- Access Board: Maneuvering Clearance at Recessed Doors
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
Beds: ADA Standard Section 224.3
Section 224.3 covers scoping requirements in the current ADA Standards for transient lodging guest room beds.
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers and sanitary napkin disposal units shall comply with Section 11B-604.7. Combination accessory units are not permitted to encroach into the space required by...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space. A clear floor...
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3.