Accessible sleeping rooms or suites that comply with the requirements of 9.2 (Requirements for Accessible Units, Sleeping Rooms, and Suites) shall be provided in conformance with the table...
Search Results "Shall"
Commonly Searched Documents
-
9.1.2 Accessible Units, Sleeping Rooms, and Suites
-
4.1.2(18)
(18) Assembly areas: (a) If places of assembly are provided, they shall comply with the following table: Capacity of Seating & Assembly Areas Number of Required...
-
EFFECTIVE COMMUNICATION DURING FACE-TO-FACE SERVICES
Beginning immediately as of the effective date of this Agreement, and pursuant to the Effective Communication Policy, THE CREDIT UNION shall provide individuals who are deaf, are hard...
-
Error/Omission: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack a fold-down seat.
Accessible sleeping rooms or suites that comply with the requirements of 9.2 (Requirements for Accessible Units, Sleeping Rooms, and Suites) shall be provided in conformance with the table...
-
§ 38.23(c)(5) Slope
Ramps shall have the least slope practicable and shall not exceed 1:4 when deployed to ground level....
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use areas, including but not limited to: Band rooms Classrooms Corridors...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-221.4 Designated aisle seats
At least 5 percent of the total number of aisle seats provided shall comply with Section 11B-802.4 and shall be the aisle seats located closest to accessible routes. ...
-
11B-809.4 Toilet facilities and bathing facilities
At least one bathroom shall comply with Section 11B-603....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 ....
-
11B-812.10.4 Location
EV chargers shall be adjacent to, and within the projected width of, the vehicle space being served. Exceptions: 1....
-
11B-239.3 Miniature golf course configuration
Miniature golf courses shall be configured so that the holes complying with Section 11B-1007.3 are consecutive....
-
11B-809.4 Toilet facilities and bathing facilities
At least one bathroom shall comply with Section 11B-603....
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use area, including but not limited to: Band rooms Classrooms Corridors Gymnasiums Lobbies...
-
11B-239.3 Miniature golf course configuration
Miniature golf courses shall be configured so that the holes complying with Section 11B-1007.3 are consecutive....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-221.4 Designated aisle seats
At least 5 percent of the total number of aisle seats provided shall comply with Section 11B-802.4 and shall be the aisle seats located closest to accessible routes....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...