Where at least one public pay telephone is provided in a public building, at least one public TTY shall be provided in the building....
Search Results "Shall"
-
11B-217.4.3.1 Public buildings
-
11B-231.3.1 Central holding cells
Where separate central holding cells are provided for adult male, juvenile male, adult female, or juvenile female, one of each type shall comply with Section 11B-807.2....
-
1131A.1 Changes in level not exceeding ½ inch
Abrupt changes in level along any accessible route shall not exceed ½ inch (12.7 mm)....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-217.4.3.2 Private buildings
Where four or more public pay telephones are provided in a private building, at least one public TTY shall be provided in the building....
-
11B-802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 11B-802.1.4 Approach....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
203.2 Construction Sites
sites directly associated with the actual processes of construction, including but not limited to, scaffolding, bridging, materials hoists, materials storage, and construction trailers shall...
-
206.2.6 Performance Areas
Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area....
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool....
-
704.4 TTYs
TTYs required at a public pay telephone shall be permanently affixed within, or adjacent to, the telephone enclosure....
-
231.3.1 Central Holding Cells
Where separate central holding cells are provided for adult male, juvenile male, adult female or juvenile female, one of each type shall comply with 807.2....
-
217.4.3.1 Public Buildings
Where at least one public pay telephone is provided in a public building, at least one public TTY shall be provided in the building....
-
213.1 General
Where toilet facilities and bathing facilities are provided, they shall comply with 213....
-
217.4.1 Bank Requirement
Where four or more public pay telephones are provided at a bank of telephones, at least one public TTY complying with 704.4 shall be provided at that bank....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
208.1 General
Where parking spaces are provided, parking spaces shall be provided in accordance with 208....
-
228.1 General
Where provided, at least one of each type of depository, vending machine, change machine, and fuel dispenser shall comply with 309....
-
802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 802.1.4 Approach....
-
206.2.17.2 Soft Contained Play Structures
Where three or fewer entry points are provided for soft contained play structures, at least one entry point shall be on an accessible route....
-
§ 382.40a Boarding assistance for large aircraft
(b) Carriers shall, in cooperation with the airports they serve, provide boarding assistance to individuals with disabilities using mechanical lifts, ramps, or other suitable devices that...
-
11B-706.3 Receiver hearing-aid compatibility
Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops....
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....