Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
Search Results "Vertical Rod"
-
1132A.4.1, Item 2
-
MEANS OF EGRESS
A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
MEANS OF EGRESS
A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
303 Changes in Level
Section 303 addresses vertical changes in level in floor or ground surfaces. No changes have been made to this section....
-
§ 1194.25(j)(1)
(1) The position of any operable control shall be determined with respect to a vertical plane, which is 48 inches in length, centered on the operable control, and at the maximum protrusion...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum vertical...
-
Permanently Installed Systems
Vertical wheelchair lifts are differentiated from elevators because they are limited in the height of their vertical lift, are not enclosed, and do not go through a floor level....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
MEANS OF EGRESS
A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
Automatic Operation [4.10.2]
Self-leveling must correct the overtravel or undertravel of a car as it stops at a landing within a ½ inch vertical tolerance since changes in level greater than ½ inch can be troublesome...
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
-
M305.3.2 Height
Horizontal standing support gripping surfaces shall comply with M305.3.2.1 and vertical standing support gripping surfaces shall comply with M305.3.2.2....
-
5.4.11 Transfer Support Structural Strength for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer supports and connections must contain the strength to resist vertical and horizontal forces of 250 pounds at locations determined by the intended use of the equipment....
-
Grade
This may be expressed as the percentage of change in elevation (grade) or as a ratio of vertical distance to horizontal distance (running slope)....