This level should not go below 70 mA/meter or above 140 mA/meter....
Search Results "Should"
-
2.1.2.1 Summary of IEC 118‒4 (1981) Standards
-
1.1.1
The dimension should be determined by the expected tolerance of the construction element....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
-
11B-1004.1 Clear floor space
To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces....
-
11B-233.3.4 Alterations
Factors to be considered in comparing one dwelling unit to another should include the number of bedrooms; amenities provided within the dwelling unit; types of common spaces provided within...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
-
Accessible Routes: ADA Standard Section 1002.2
Where possible, the least possible slope should be used on the accessible route that serves the amusement ride....
-
11B-216.3 Directional and informational signs
It should be noted that exterior signs are likely to be viewed at a greater distance than interior signs, which would affect the prescribed height of visual characters....
-
11B-1004.1 Clear floor space
To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces....
-
11B-216.3 Directional and informational signs
It should be noted that exterior signs are likely to be viewed at a greater distance than interior signs, which would affect the prescribed height of visual characters....
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.
-
11B-809.4 Toilet facilities and bathing facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. ◼...
-
11B-233.3.4 Alterations
Factors to be considered in comparing one dwelling unit to another should include the number of bedrooms; amenities provided within the dwelling unit; types of common spaces provided within...
-
11B-809.4 Toilet facilities and bathing facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. ◼...
-
11B-703.2 Raised characters
Signs that are designed to be read by touch should not have sharp or abrasive edges....
-
Question 19
Should the Department regulate effective communication from such facilities? What are the costs associated with various types of EIT in such settings?...
-
F245.2 Picnic Units with Mobility Features
Entities should provide information on the location of picnic units with mobility features on websites, in brochures, and at bulletin boards or information kiosks at the picnic facility....
-
11B-703.2 Raised characters
Signs that are designed to be read by touch should not have sharp or abrasive edges. ◼...
-
Issue 4: Wrong pole! …Wrong message!
Remedy: Each APS should have been installed on the pole closest to the crosswalk it controls, as shown in Figure 8 (pushbutton for street on right is on the back side of the pole, out of...
-
K) Temporary Events
When planning temporary events such as a town festival or concert, the town should review ADA title II requirements 2 and the ADA Standards....
-
2.1.2.2 Additional Proposed Specifications (by Oval Window Audio)
At least 80% of the installed loop should be free of the influences of metal, either in front of, or immediately behind the wire. 2....
-
§ 36.604(a)(1)
individuals with disabilities, during a period of at least 60 days following publication of the notice, to file written comments relevant to whether a final certification of equivalency should...
-
Technical Requirements
Commenters indicated that provisions specific to courtrooms in section 232.2 of the proposed rule functioned more as technical requirements and should be relocated to the appropriate technical...