[See subsections ...]
Search Results "Out-Swinging Door"
Commonly Searched Documents
-
11B-404 Doors, doorways, and gates
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
Re: 11B-904.3.4 Identification sign
when displayed, this section refers to "heck out aisles" instead of check out aisles...
-
GameTime Adaptive Swing Seat
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Accessible entrances that have turnstiles must provide an accessible gate or door.
• Accessible entrances that have turnstiles must provide an accessible gate or door....
-
Door King Inc. 6004 Column Mount Swing Gate Operator Solar Powered
Requires the Registered User plan or above. Login!
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
3. Measuring Door Openings
Measuring Door Openings Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
III-7.8400 Business and mercantile
What does "one of each type" mean in a store where computerized check-out permits universal service at any cash register?...
-
End-of-Row Stalls
If an out swinging door is provided at an end-of-row stall, maneuvering space of at least 18 inches at the latch side pull side must be provided....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
Sections 5 Through 9 (Preamble, Section-by-Section Analysis)
., Check-out Aisles, provides that, in new construction, a certain number of each design of check-out aisle, as listed in a chart based on the total number of checkout aisles of each design...
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
4.13.12* Automatic Doors and Power-Assisted Doors
If an automatic door is used, then it shall comply with ANSI/BHMA A156.10‒1985. Slowly opening, low-powered, automatic doors shall comply with ANSI A156.19‒1984....
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
Section D: Entrances
opening (one door or one active leaf of a double door) at least 32"?...