1132A.8 Hand-activated door hardware. Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
Search Results "Open Doors Organization"
-
1132A.8 Hand-activated door hardware
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
- Tormax Technologies iMotion® TN 110 In-Floor Swing Door Operator (High and Low Energy)
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
1.4.4. Operational Requirements
Because movie theaters may comply with the requirement to provide captioning at all screenings of a digital movie produced or distributed with such features through the provision of open...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
Door and Gate Hardware [§404.2.7]
Door and Gate Hardware [§404.2.7] Door and gate hardware must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate...
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
Openings in the surface of the clear ground space must be small enough so that a sphere more than one-half inch in diameter cannot pass through....
-
304.4 Door Swing
304.4 Door Swing. Doors shall be permitted to swing into turning spaces....
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....