Is there vertical clearance of at least 114 inches (9 feet 6 inches) from the site entrance to the vehicle pull-up area, the access aisle, and along the vehicle route to the exit?...
Search Results "Exit"
-
A4
-
4.1.3(8)(b) Note
Because entrances also serve as emergency exits whose proximity to all parts of buildings and facilities is essential, it is preferable that all entrances be accessible....
-
Catch Pools
An accessible means of entry or exit is not required into the catch pool. However, an accessible route must connect to the edge of the catch pool....
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures and exit...
-
Separate Tenancies
This is required even where it would increase the minimum number above the number of required exits or 50% of facility entrances....
-
IS ASSISTANCE REQUIRED?
Once notified, people with a speech disability can read and follow standard exit and directional signs and use any standard means of egress from the building....
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
Path of Travel
35.151(b)(4)(ii) & 36.403(e)] (1) A "path of travel" includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited...
-
Weather Shelters
Weather Shelters Course weather shelters must be designed and constructed to allow a golf car to enter and exit, and have a clear floor or ground space of 60 inches by 96 inches minimum...
-
F206.2.16.1 Ground Level and Elevated Play Components
The accessible route shall connect ground level play components required to comply with F240.2.1 and elevated play components required to comply with F240.2.2, including entry and exit points...
-
USE ZONE
structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
-
USE ZONE
structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
-
206.2.17.1 Ground Level and Elevated Play Components
The accessible route shall connect ground level play components required to comply with 240.2.1 and elevated play components required to comply with 240.2.2, including entry and exit points...
-
18) Elevators and platform lifts in new construction and alterations
Individuals must be able to enter unassisted, operate, and exit the lift without assistance (4.11.3)....
-
5) Areas of rescue assistance or places of refuge
An accessible egress route or an area of rescue assistance is required for each exit required by the local fire code....
-
Sec.36.403(e)(1)
(1) A "path of travel'' includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
§ 36.403(e)(1)
(1) A "path of travel" includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
7(2)(b)(ii)
There also shall be clear space to allow persons using wheelchairs to reopen the door to exit....
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
- TownSteel ED5500F Grade 1 Fire Rim Device
-
USE ZONE
structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
M303.2.6 Edge Protection
more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side not providing entry to or exit...