route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum clear...
Search Results "Clear"
-
§ 38.57(b)
-
Voting Areas
There also must be enough clear floor space in at least one voting station or booth to allow a voter using a wheelchair or other mobility device to approach, maneuver, and leave the voting...
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
R212.6 Benches
At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures" (323...
-
R404.7 Maneuvering Space
Where a clear space is confined on all or part of three sides, additional maneuvering space shall be provided in accordance with R404.7.1 and R404.7.2....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
7a.
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
g-i
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No...
-
5.3 Access Aisles
All accessible fixed tables shall be accessible by means of an access aisle at least 36 in (915 mm) clear between parallel edges of tables or between a wall and the table edges....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....