213.3 Plumbing Fixtures and Accessories. Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3.
Search Results "Built-In Element"
Commonly Searched Documents
-
213.3 Plumbing Fixtures and Accessories
-
606.3 Height
606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the...
-
9.1.2 Accessible Units, Sleeping Rooms, and Suites
Accessible sleeping rooms or suites that comply with the requirements of 9.2 (Requirements for Accessible Units, Sleeping Rooms, and Suites) shall be provided in conformance with the...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. Advisory 11B-213.3...
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures. Exception: When an entire seating section is placed on temporary...
-
11B-608.5.2 Standard roll-in type shower compartments
11B-608.5.2 Standard roll-in type shower compartments. In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the...
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures. Exception: When an entire seating section is placed on temporary...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. Advisory 11B-213.3...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches...
- #CrappyCurb
-
11B-502.4 Floor or ground surfaces
Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48. ◼ Advisory 11B-502.4 Floor or ground surfaces...
-
11B-805 Medical care and long-term care facilities
the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in...
-
Spaces and Elements: ADA Standard Section 206.2.4
Section 206.2.4 covers the scoping requirements in the most current ADA Standards for accessible routes connecting spaces and elements within a building.
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483...
-
Shower Compartments
Shower Compartments. The 1991 Standards at sections 4.21 and 9.1.2 and the 2010 Standards at section 608 contain technical requirements for transfer-type and roll-in shower...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the...
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar,...
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves,...
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the...
-
11B-604.3.2 Overlap
11B-604.3.2 Overlap. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units,...
-
11B-608.5.3 Alternate roll-in type shower compartments
11B-608.5.3 Alternate roll-in type shower compartments. In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of...