11B-407.2.1.4 Location
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
Section 35.151(f) Housing at a place of education (Section-by-Section Analysis)
There are other differences between the two sets of standards as well with respect to requirements for accessible windows, alterations, kitchens, accessible route throughout a unit, and clear...
- AJW Architectural Products U701 Series Frameless Mirror
- HEWI System 100 Door Hardware
- HEWI Range 260 Door Hardware
- Texas Department of Licensing and Regulation (TDLR)
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
e-i
Are the centerlines of the call buttons mounted 42 inches above the floor? [ADA Standards § 4.10.3] Yes No...
-
H19
Is the top of the toilet seat 17 inches to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No...
-
Section 2. Loft
"Loft" means an intermediate level between the floor and ceiling of any story, located within a room or rooms of a dwelling....
-
4.18.2 HEIGHT
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
M301.4.2 Clearance Around Base (Section-by-Section Analysis)
The MDE NPRM proposed certain requirements to provide clearance around the base of the diagnostic equipment to allow the legs of the portable floor lift to straddle the base of the diagnostic...
-
225.3 Storage
Facilities with 200 or fewer storage spaces will be required to make at least five percent (5%) of the storage spaces accessible....
-
F225.3.1 Dispersion
Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided....
-
225.3.1 Dispersion
Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided....
-
11B-502.3.4 Location
spaces...
-
11B-502.3.4 Location
spaces...
-
11B-502.3.4 Location
spaces...