Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
Search Results "Sign Clear Floor Space"
-
1132A.3 Width and height of interior doors and secondary exterior doors
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface....
-
Serving Counters
Serving Counters Where food or drinks are served at counters and the counter height is more than 34 inches above the floor, providing a lowered section of the serving counter at least...
-
Use of Accompanying Adults or Children as Interpreters
Use of Accompanying Adults or Children as Interpreters Historically, many covered entities have expected a person who uses sign language to bring a family member or friend to interpret...
-
§382.35(b)
(b) You must not require passengers with a disability to sign waivers of liability for damage to or loss of wheelchairs or other assistive devices, or for the loss of, death of, or injury...
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
Getting From Here to There—Outdoor Recreation Access Routes
Design outdoor recreation access routes to meet technical requirements for running and cross slopes, resting intervals, surface, clear tread width, passing spaces, tread obstacles, protruding...
-
BACKGROUND
(the “Complainant”), who is deaf, alleged that AFAC personnel failed to provide sign language interpretive services during multiple medical appointments, including pre- and post-surgery...
-
Communicating with People Who are Deaf or Hard of Hearing
A sign language interpreter can be used when speaking with a person who knows sign language....
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
11B-703.2 Raised characters