Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
Search Results "Sign Clear Floor Space"
-
11B-803.6 Mirrors
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
Car Controls
...are the highest floor control buttons in the elevator(s) mounted within 54" of the floor, with associated raised letters and Braille characters?...
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
§100.75(b)
Written notices and statements include any applications, flyers, brochures, deeds, signs, banners, posters, billboards or any documents used with respect to the sale or rental of a dwelling...
-
§ 38.27(a)
(a) Each vehicle shall contain sign(s) which indicate that seats in the front of the vehicle are priority seats for persons with disabilities, and that other passengers should make such...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
Use of Accompanying Adults or Children as Interpreters
Use of Accompanying Adults or Children as Interpreters Historically, many covered entities have expected a person who uses sign language to bring a family member or friend to interpret...
-
12101(b)(1)
(1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities;...
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
General Tips
Keep a clipboard or other portable writing surface handy for people unable to reach the counter when signing documents....
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-217.2 Wheelchair accessible telephones
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES NUMBER OF TELEPHONES PROVIDED ON A FLOOR, LEVEL, OR EXTERIOR SITE MINIMUM NUMBER OF REQUIRED WHEELCHAIR...
-
11B-217.2 Wheelchair accessible telephones
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES Number Of Telephones Provided On A Floor, Level, Or Exterior Site Minimum Number Of Required Wheelchair Accessible Telephones...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed certain clearance requirements beneath the diagnostic equipment to allow sufficient space for the legs of a portable patient lift to fit underneath the equipment so...