opportunities which incorporate portable seating, while gaining knowledge of ADA solutions, sightlines, seat options and accessories associated with portable seating solutions for multi-use facilities...
Search Results "Housing Facility"
Commonly Searched Documents
-
Designing & Configuration Trends with Portable Chair Seating for Places of Assembly Continuing Education Course
-
4.1.4(5) BUSINESS
Facilities Animal hospitals, kennels, pounds Automobile and other motor vehicle showrooms Banks Barber shops Beauty shops Car wash Civic administration Clinic, outpatient...
-
Can doors swing into required clear floor or ground space?
ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5) fixture clearances in toilet and bathing facilities...
-
Are freight or service elevators required to comply?
Examples include elevators in residential or retail facilities that are regularly used by tenants or customers but that are also used to move furniture, merchandise, or other freight....
-
11B-505.4 Height
When children are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate height can assist them and aid in preventing accidents...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1009.4 Elevators
Areas of refuge are not required in buildings and facilities equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2....
-
11B-806.3 Guest rooms with communication features
To ensure communication within the facility, as well as on commercial lines, provide telephone interface jacks that are compatible with both digital and analog signal use....
-
11B-806.3 Guest rooms with communication features
To ensure communication within the facility, as well as on commercial lines, provide telephone interface jacks that are compatible with both digital and analog signal use....
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
11B-505.4 Height
When children are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate height can assist them and aid in preventing accidents...
-
Safe Harbors
The requirements for Title II, State and Local Government Facilities, are similar and may be found at 28 CFR Part 35 §35.150(b)(2)(i)....
-
1003.3.1 Boat Slip Clearance
In existing piers, clear pier space shall be permitted to be located perpendicular to the boat slip and shall extend the width of the boat slip, where the facility has at least one boat...
-
Resources
ADA Checklist for New Lodging Facilities. Retrieved from http://www.ada.gov/hsurvey.htm Department of Justice (2001, January). Serving Guests who are Blind or Have Low Vision....
-
Self-evaluation
Survey facilities and determine whether there are physical barriers to access programs. If structural changes are needed, include them in the transition plan....
-
Regulatory Process Matters
) of this rule and the Architectural and Transportation Barriers Compliance Board is preparing an RIA for its Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities...
-
Infrared Systems
There is no spillover to nearby systems and all transmitters and receivers in a facility can be tuned alike, an important consideration where multiple systems are provided in a facility....
-
Cost Estimates for Barrier Removal
They have been verified and updated through eight years of surveying in a variety of facilities nationwide....
-
Inquiries, Exclusions, Charges, and Other Specific Rules Related to Service Animals
When a person who is allergic to dog dander and a person who uses a service animal must spend time in the same room or facility, for example, in a school classroom or at a homeless shelter...
-
Conclusions and Recommendations
On the encouraging side, most participants had a good understanding of the problems that older individuals and caregivers face with accessibility to toileting and bathing facilities....
-
Introduction
The ADA requires that new construction and alterations to existing facilities comply with the ADA Standards for Accessible Design 1 (Standards)....
-
Reach Ranges
These comments argued that the new reach range requirements restrict design options, especially in residential housing....
-
Chapter 1 GENERAL INFORMATION
This Guide was developed using the five general categories of disabilities recognized in the Fair Housing Act Design Manual....
-
Issue 19: What Principles of Universal Design can be applied in the short term for persons with low vision?
guidelines written down somewhere that, you know, when someone comes in and they say, yeah, I have trouble in the kitchen, they say, well, you know, if you really want to stay in your house...