telecommunications equipment and customer premises equipment are required by §255 of the Telecommunications Act of 1966 to "ensure that the equipment is designed, developed and fabricated to be accessible...
Search Results "Accessible Route"
-
Covered Entities
-
What other considerations are significant for persons with disabilities?
Thus, walks surfaced in these materials could not constitute an accessible route....
-
Alterations Affecting Primary Function Areas: ADA Standard Section 202.4
Section 202.4 covers the most current ADA Standards for alterations affecting primary function area.
-
a) Aquatic Program
Wood credibly opined that renovated pools have the features necessary to provide program access, namely: (1) an accessible route from the property line to the building; (2) an accessible...
-
Historic Preservation [4.1.7]
These requirements address accessible routes, ramps, entrances, toilet rooms, access between floors, and displays....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn,...
-
11B-1002.4.4 Clearances
This exception for protruding objects applies to the ride devices, not to circulation areas or accessible routes in the queue lines or the load and unload areas....
-
Protrusions
Protrusions There may be some protrusions into wheelchair spaces on rides, but not into circulation areas, accessible routes,or load and unload areas....
-
Comments
The rationale for doing so, they said, is the same as in the case of fixed route vehicles: simply acquiring inaccessible used vehicles perpetuates transportation that is not fully accessible...
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
R304.2.3 Flared Sides
The flared sides are part of the pedestrian circulation path, but are not part of the pedestrian access route....
-
Ramps [4.8]
Where the running slope of an accessible route is more than 5%, it is considered a ramp. Generally, changes in level up to 6 inches can be treated as a curb ramp....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
§ 37.103(d) Vans with a capacity of fewer than 8 persons
If the entity operates either a fixed route or demand responsive system, and purchases or leases a new van with a seating capacity of fewer than eight persons including the driver (the solicitation...
-
11B-1002.4.4 Clearances
This exception for protruding objects applies to the ride devices, not to circulation areas or accessible routes in the queue lines or the load and unload areas....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-226.4 Baby changing tables
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...