gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
11B-404.2.11 Vision lights
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
Obstructions [4.7.8]
A landing with a minimum length of 48 inches will provide sufficient turning space....
-
Are redundant controls for an element required to comply?
If redundant controls, other than light switches, serve a single element, one control in each space is not required to comply....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
F217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
F211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with F211....
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
(5) Reinforced walls for grab bars
The only change made to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a...
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
§ 38.93(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
- Xpress II Inclined Platform Wheelchair Lift
- Kompan, Inc. Multi-sport Game Courts Freegame Court FRE2110
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
-
2.3
Consent Order after the Effective Date of this Consent Order, these theaters, in each case, shall be in compliance with the requirements of the ADA with respect to (a) providing wheelchair spaces...
-
216 Signs
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5....
-
Accessible Routes
Accessible Routes ADAAG requires that at least one accessible route connect accessible buildings, facilities, elements and spaces on the site....