Stair treads must meet requirements for floor or ground surfaces which specify that surface openings not allow passage of a sphere more than ½ inch in diameter (§302.3)....
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
Can stair treads and risers be perforated?
-
§ 38.73(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
- Rebuilding Together Saratoga County - Wilton, NY
-
11B-208.3.1 General
Parking spaces complying with Section 11B-502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with Section...
-
11B-208.3.1 General
Parking spaces complying with Section 11B-502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with Section...
-
11B-221.6 Semi-ambulant seats
served by an accessible route; (2) Assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards...
-
11B-221.6 Semi-ambulant seats
served by an accessible route; (2) Assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards...
-
11B-221.6 Semi-ambulant seats
In addition, assembly areas shall ensure that — 1) In stadiums, arenas, and grandstands, wheelchair spaces and companion seats are dispersed to all levels that include seating served...
-
NFPA: ADA Standard Section 105.2.5
Section 105.2.5 of the ADA Standards cover references to the National Fire Protection Association (NFPA).
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
11B-809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
General (R309.1) (Section-by-Section Analysis)
General (R309.1) (Section-by-Section Analysis) The technical requirements for accessible on-street parking spaces are contained in R309 and adapt the technical requirements for accessible...
-
F246.4 Outdoor Recreation Access Routes
This section requires at least one outdoor recreation access route to connect accessible parking spaces or other site arrival points serving the viewing area with accessible elements, spaces...
-
Is accessible parking required on sites where no parking is intended?
No, the ADA Standards require accessible spaces only where parking is provided. They do not require accessible spaces where parking is not provided at all....
-
Are bollards, poles, columns, or other elements permitted within the marked area of access aisles?
(The width of spaces and aisles is measured to the centerline of markings but can include the full line width where there is no adjacent parking space or aisle)....
-
11B-809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
11B-809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
11B-604.7 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....