The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
Search Results "Portable Patient Lift"
-
M301.1 General (Section-by-Section Analysis)
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
M301.2.2, M302.2.2 Transfer Size
M301.2.2, M302.2.2 Transfer Size Proposed requirement: 30" wide minimum and 15" deep minimum • Sub-Committee Recommendation: 28" wide minimum and 17" deep minimum. This...
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
Scoping [4.1.3(19)]
Requirements for portable assistive listening systems (outlets and wiring) may apply to areas without fixed seating....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
704.3 Volume Control Telephones
Portable and in-line amplifiers can be used with some phones but are not practical at most public phones covered by these requirements....
-
Section 37.165 Lift and Securement Use
A lift conforming to Access Board requirements has a platform measuring at least 30” x 48”, with a design load of at least 600 pounds (i.e., capable of lifting a wheelchair/occupant combination...
-
16. I think a lift poses a safety risk at an unattended pool. I also have heard that my insurance rates will increase if I have a lift in my unattended pool. Can I consider safety risks?
I think a lift poses a safety risk at an unattended pool. I also have heard that my insurance rates will increase if I have a lift in my unattended pool....
-
§ 38.83(b)(4) Power or equipment failure
Lift platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second...
-
Platform to Runway Clearance: ADA Standard Section 410.4
Section 410.4 covers the current ADA Standards for the required clearance between the platform and any runway landing.
-
Seat Location: ADA Standard Section 1009.2.2
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.
- CommonLook by NetCentric Technologies
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the...
-
General
General Because many patients in a medical care facility may experience reduced mobility during their stay, at least 10% of patient bedrooms and in-room bathrooms must be fully accessible...
-
704.3 Volume Control Telephones
Portable and in-line amplifiers can be used with some phones but are not practical at most public phones covered by these requirements....