Speak to the individual when you approach him or her. State clearly who you are; speak in a normal tone of voice. When conversing in a group, remember to...
Search Results "Low Energy Door"
Commonly Searched Documents
-
Tips for Communicating with Individuals Who are Blind or Visually Impaired
-
Stairs, short-term list
I’ll put one up there, short-term, stairs. Stairs is a tangible safety issue and in fact the code has elements of some of the things that we’ve just described as better practices...
-
Lighting Contrast and Conceptual Design
Comment by Vijay Gupta: I wanted to [continue] discussing [the] earliest availability of standards or [guidelines] which are already on hand. So your panel has done a good job. There...
-
302.2 With Limited Vision
Where a visual mode of operation is provided, ICT shall provide at least one mode of operation that enables users to make use of limited vision.
-
302.2 With Limited Vision
Where a visual mode of operation is provided, ICT shall provide at least one mode of operation that magnifies, one mode that reduces the field of vision required, and one mode that...
-
A4.10.12 Car Controls
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments. In many cases,...
-
A4.10.12 CAR CONTROLS
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments. In many...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
- ADAEZ Pro Plus Automatic Door Opener Installing the Door Decals Video
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
4.13.1 General
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
4.13.1 GENERAL
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors....
-
4.1.3(7)(a)
(a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...