Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
Search Results "Informational Signage"
-
11B-703.7.2.3 Volume control telephones
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-703.7.2.2 International Symbol of TTY
The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
Volume Control Telephones: ADA Standard Section 703.7.2.3
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 703.7.2.3.
-
Case: ADA Standard Section 703.2.2
Characters shall be uppercase.
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
E101.1 Purpose
These 508 Standards, which consist of 508 Chapters 1 and 2 (Appendix A), along with Chapters 3 through 6 (Appendix C), contain scoping and technical requirements for information and communication...
-
E101.1 Purpose
These Revised 508 Standards, which consist of 508 Chapters 1 and 2 (Appendix A), along with Chapters 3 through 7 (Appendix C), contain scoping and technical requirements for information...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.4.2 Location
11B-703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
- Access Board: Tactile Sign Clear Floor Space
-
11B-703.1.1.1 Plan review
Plans, specifications or other information indicating compliance with these regulations shall be submitted to the enforcing agency for review and approval....
-
11B-703.1.1.1 Plan review
Plans, specifications or other information indicating compliance with these regulations shall be submitted to the enforcing agency for review and approval....
-
F216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
At least fifty percent of the entrances must be accessible.
• At least fifty percent of the entrances must be accessible. Those that are not accessible must have signs that direct the public to the nearest accessible entrance.