When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
Search Results "Horizontal Dispersion"
Commonly Searched Documents
-
§ 38.95(b)(7) Platform gaps
-
§ 38.125(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. ◼...
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet  compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so....
-
233 Residential Facilities, F233 Residential Facilities
233.3.6 Dispersion   ABA Scoping Requirements F233 Residential Facilities F233 Residential Facilities F233.1 General F233.1 General ...
- Don-Jo Mfg., Inc. 2-3/4" Hospital Latch 4500
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
f-v
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided at every 30 feet of horizontal length?...
-
4d.
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length?...
-
6d. Ramp Length
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length?...
-
Extensions
Handrails that are not continuous must have horizontal extensions at both the top and bottom of the ramp at least 12 inches long that are rounded or returned smoothly to walls, posts, or...
-
11B-809.10.5.2 Reinforcement for grab bars
Grab bar backing shall be installed horizontally to permit the installation of a 48-inch (1219 mm) grab bar with each end 6 inches (152 mm) maximum from the end walls of the bathtub....
-
Handrail Requirements
An exception permitted brackets and balusters attached to the bottom of a handrail provided they did not obstruct more than 20% of the handrail length, their horizontal projection was at...
-
Transfer Sides (M301.2.3 and M302.2.3)
This is consistent with ANSI/AAMI HE 75 which recommends that the “base of any patient-support platform should not extend horizontally beyond the edge of the support surface . . ....
-
3. Buttock-Popliteal Length
Buttock-Popliteal Length For this study, an estimate of buttock-popliteal length was calculated as the horizontal distance from the proximal (rear) edge of the wheelchair seat cushion...
-
404.2.10 Door and Gate Surfaces
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other. Cavities created by added kick plates shall be capped....
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical and horizontal...
-
711.3.2 Membrane penetrations
By a horizontal distance of not less than 24 inches (610 mm); 1.2....
-
404.2.10 Door and Gate Surfaces
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other....
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M305.2.2 would require the transfer supports and their connections to be capable of resisting vertical and horizontal forces of 250 pounds applied to all points of the transfer support....
-
11B-903.4 Back support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. [2010 ADAS] 903.4 Back Support....
-
11B-903.4 Back support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. [2010 ADA Standards] 903.4 Back Support....
- Hager Companies Push/Pull Latch 311L
-
F216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...