Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
Search Results "Ground Floor Exit"
Commonly Searched Documents
-
803.3 Door Swing
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
- PEMKO 6 1/8" Floor Plates/Safety Treads No. 193
- PEMKO 6-1/8" Floor Plates/Safety Treads No.19325
- PEMKO 5 29/32" Floor Plates/Safety Treads No. 2266
- PEMKO 9 1/2" Floor Plates/Safety Treads No. 2286
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV. 3....
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV....
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
106.5.69 Teeing Ground
In golf, the starting place for the hole to be played.
-
Space Allowance and Reach Ranges [4.2]
Adult dimensions and measures for standard manual wheelchairs form the basis of many ADAAG specifications. For example, the specified height of toilets and shower seats (17-19...
-
Dimensional Tolerances in Construction and for Surface Accessibility
[See subsections ...]
-
1015.2 Clear Ground Space
This section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for either a forward or parallel approach to be provided at each distinct viewing location, and...
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
ADA Gap Tool
ADA Gap Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring gaps in ground or floor surfaces....
- Allen Face F-Meter® Rolling Floor Profiler
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1003.2.13.2 Enclosed stairways
considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level...