Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
Search Results "Entry Point"
-
11B-608.2.3 Alternate roll-in type shower compartments
-
Door Closers [4.13.10]
Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be slow enough to allow entry...
-
Press Boxes [§206.2.7]
playing field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade at least 12’ or located in bleachers with points...
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
- Access Board: Sales and Service Counters
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Are access key, card, or code entry systems permitted in elevators?
Yes, but fixed features of such systems must comply as operable parts. For example, card readers must be located within accessible reach ranges. Non-fixed portions, including keys...
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
20. Does topping off a play surface trigger its replacement with an accessible surface?
Changing the surface type or replacement of the surface would require an accessible surface along accessible routes located within the boundary of the play area, including the entry and...
-
7. Should overhead play components such as track riders, ring ladders, monkey bars, and chin up bars be lowered to the recommended reach ranges?
Overhead play components that are required to have their entry and exit points connected by an accessible route are not required to be lowered to be considered accessible....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
Accessible Classroom - Chevron Style
Chevron style allows better line of sight for speakers and attendees and easier entry for those using mobility devices....
- Liberty Resources, Inc - Philadelphia and Allentown, PA
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
residential dwelling units shall be calculated using the total number of multi-story residential dwelling units in buildings on a site and shall comply with the following: The primary entry...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
residential dwelling units shall be calculated using the total number of multi-story residential dwelling units in buildings on a site and shall comply with the following: The primary entry...
-
Visually IMpaired Accessible Keypad Door Lock
nextouch-keypad-lock/ Best I can tell there is no reference in the CBC or the ADA Guidelines that applies (confirmed with the access board) Thinking I will recommend that the owner obtain a keypad entry...
-
Issue 13: How can energy codes and LEED™ “Points” be made compatible with lighting design criteria that accommodate low vision persons?
are public spaces or circulation areas, and the energy codes are restricting you to half a watt a square foot, so it’s very restrictive in terms of light levels that you can provide in entry...
-
Seat width and depth
Seat width and depth: ADA-ABA currently requires a minimum entry point of 24 inches for transfer steps in play (Section 1008.3.1.1) [7] and pool areas (Section 1009.4.5) [7]. ...