Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
Search Results "Dwelling Unit (FHA)"
-
1132A.8 Hand-activated door hardware
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1150A.1 General
Except as provided for in Section 1102A.3.1, the provisions of this section do not apply to multistory dwelling units in non-elevator buildings....
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
11B-809.10.6.3 Clearance
Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Amendments increase clear floor space at showers in residential dwelling...
-
13.1 Q. Are the public and common use areas of a newly constructed development that consists entirely of buildings having four or more multistory townhouses, with no elevators, required to be accessible?
The Fair Housing Act applies only to new construction of covered multifamily dwellings....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
Transient Lodging
A building, facility, or portion thereof, excluding inpatient medical care facilities, that contains one or more dwelling units or sleeping accommodations....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
1133A.4 Countertops
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....