Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum...
Search Results "Drinking Fountain Spout Height"
Commonly Searched Documents
- 
    
  
  11B-607.4.2.1 Back wall
  
- 
    
  
  11B-607.4.1.1 Back wall
  Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum... 
- 
    
  
  11B-407.4.8.1.1 Size
  Characters shall be ½ inch (12.7 mm) high minimum. 
- Smith System Husky Rectangle Activity Table 24″ Deep
- 
    
  
  Benches
  The seat height should be a minimum of 17 inches to a maximum of 19 inches above the finished floor.... 
- Populas Accella Adjustable Activity / Computer Workstation
- Smith System Lift Desk Work Surface with Crank
- Populas Vox Perfect Corner Workstation
- 
    
  
  Implication for Standards and Design
  Moreover, the second phase transfer station allowed for evaluating the presence/absence of various height grab bars, a backrest added in parallel to the front edge of the transfer surface... 
- Figure 703.4.1 Height of Tactile Character Above Finish Floor or Ground – Drawing from the U.S. Access Board
- 
    
  
  4. Breast Platform Adjustability
  The MDE Advisory Committee recommended changing the breast platform height requirement from a specified height range to a required minimum range bounded by a required high height of 42 inches... 
- 
    
  
  M301.2.1 Adjustability (Section-by-Section Analysis)
  The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum.... 
- 
    
  
  1134A.7, Item 3
  Seat height. The minimum height of water closet seats shall be 15 inches (381 mm) above the floor.... 
- 
    
  
  1134A.7, Item 3
  Seat height. The minimum height of water closet seats shall be 15 inches (381 mm) above the floor.... 
- 
    
  
  11B-504.2 Treads and risers
  All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum.... 
- 
    
  
  11B-504.2 Treads and risers
  All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum.... 
- 
    
  
  11B-504.2 Treads and risers
  All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum.... 
- 
    
  
  1005.2.1 Height
  At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections... 
- 
    
  
  1005.2.1 Height
  At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections... 
- 
    
  
  11B-703.5.5 Character height
  11B-703.5.5 Character height. Minimum character height shall comply with Table 11B-703.5.5.... 
- 
    
  
  402.4 Characters (Section-by-Section Analysis)
  In addition, where ICT does not provide a screen enlargement feature, characters would be required to have a minimum height requirement of 3/16 inch based on the uppercase letter “I.”... 
- 
    
  
  Addendum D: Comparison of demographics and transfer height between Phase 1 and Phase 2 of the study
  [See subsections ...] 
- 
    
  
  § 35.151(b)(4)(iv)(B)(5) Accessible drinking fountains
  (5) Accessible drinking fountains; and... 
- 
    
  
  M301.2.2 Sunset Provision (Section-by-Section Analysis)
  (Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new requirement of a low height range in M301.2.1... 