11B-404 Doors, doorways, and gates
-
11B-404 Doors, doorways, and gates
[See subsections ...]
- ACS Captioning and Closed Captioning Services
-
§ 36.303(e) Closed caption decoders
(e) Closed caption decoders....
-
Accessible entrances that have turnstiles must provide an accessible gate or door.
• Accessible entrances that have turnstiles must provide an accessible gate or door....
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
Can doors swing into turning space?
Yes, doors can swing into turning space....
-
3. Measuring Door Openings
Measuring Door Openings Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
C. Clear Floor Space
When there is a vestibule into the public or employee restroom that does not have fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged...
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....