The 30-inch dimension is based on the width of a stationary occupied wheelchair....
Search Results "Dimension Range"
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of manual chair (n=276), power chair (n=189), and scooter (n=30) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
The accompanying table provides dimensions values for clear floor area to accommodate 95% of scooter (n=30), power chair (n=189), and manual chair (n=276) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of power chair (n=189), scooter (n=30), and manual chair (n=276), users that were measured as part...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points.18 In practical terms, because...
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....
-
General: ADA Standard Section 606.1
Section 606.1 of the ADA Standards covers information in the current ADA Standards for lavatories and sinks.
-
M305.2.4 Cross Section (Section-by-Section Analysis)
of 2 inches maximum, and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
Grab bars with non-circular cross sections must have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
The transfer surface dimensions do not include headrests, footrests, or similar supports for body extremities that do not support the patient’s overall body position....
-
§ 36.311(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
-
§ 35.137(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
-
4.3.3 Clear Floor Area
The 95th percentile dimension values for occupied length and breadth provide a reasonable threshold value for determining the dimensions for clear floor area length and breadth....
- Diadema 80 Interior Wall Sconce by Hampstead
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Section 4.26.2
Handrail gripping surfaces with a non-circular cross section must have a perimeter dimension of 4 inches to 6 ¼ inches, and a cross section dimension of 2 ¼ inches maximum....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....