The 30-inch dimension is based on the width of a stationary occupied wheelchair....
Search Results "Dimension Range"
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of manual chair (n=276), power chair (n=189), and scooter (n=30) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
The accompanying table provides dimensions values for clear floor area to accommodate 95% of scooter (n=30), power chair (n=189), and manual chair (n=276) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of power chair (n=189), scooter (n=30), and manual chair (n=276), users that were measured as part...
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
General: ADA Standard Section 606.1
Section 606.1 of the ADA Standards covers information in the current ADA Standards for lavatories and sinks.
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points.18 In practical terms, because...
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
It's like what Daniel is describing but I'm not sure about the exact dimensions or construction details of the one in these photos....
-
M305.2.4 Cross Section (Section-by-Section Analysis)
of 2 inches maximum, and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
Grab bars with non-circular cross sections must have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
§ 36.311(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
-
§ 35.137(b)(2)(i)
(i) The type, size, weight, dimensions, and speed of the device;...
- Diadema 80 Interior Wall Sconce by Hampstead
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
The transfer surface dimensions do not include headrests, footrests, or similar supports for body extremities that do not support the patient’s overall body position....
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
4.3.3 Clear Floor Area
The 95th percentile dimension values for occupied length and breadth provide a reasonable threshold value for determining the dimensions for clear floor area length and breadth....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Section 4.26.2
Handrail gripping surfaces with a non-circular cross section must have a perimeter dimension of 4 inches to 6 ¼ inches, and a cross section dimension of 2 ¼ inches maximum....