The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
Search Results "Character Style (Visual)"
Commonly Searched Documents
-
11B-809.5.3 Interconnection
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
[F] 907.5.2.3.2 Groups R-1 and R-2.1. Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4....
-
707.6.2 Numeric Keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4....
-
707.6.2 Numeric Keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
-
11B-707.6.2 Numeric keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
-
11B-707.6.2 Numeric keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
-
707.6.2 Numeric Keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
-
11B-707.6.2 Numeric keys
Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the...
- Innerface ARQ Interior Sign Frame System
- Innerface Clearview Interior Signage
-
§27.71(k)(3)(ii) Timing.
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
§ 27.71(k)(3)(ii) Timing
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
Section 35.151(g) Assembly Areas (Section-by-Section Analysis)
Section 35.151(g)(4) would provide more precise guidance for designers of stadium-style movie theaters by requiring such facilities to locate wheelchair seating spaces and companion seating...
-
Figure 11B-407.2.3.1 Floor designation
SECTION TITLE NOTES Figure 11B-407.2.3.1 Floor designation. Revises the braille...
-
§382.69 What requirements must carriers meet concerning the accessibility of videos, DVDs, and other audio-visual presentations shown on-aircraft to individuals who are deaf or hard of hearing?
[See subsections ...]
- Takeform Fusion Signage Office/Suite/Room Identification Type G
- Takeform Fusion Signage Office/Suite/Room Identification Type F
- Takeform Fusion Signage Office/Suite/Room Identification Type G.2