Sensory Impairments: Employers should install lighted fire strobes and other visual or vibrating alerting devices to supplement audible alarms....
Search Results "Character Height (Visual)"
-
Sensory Impairments
-
a. Transfer Surface Adjustability
The Board considered it likely that diagnostic equipment would be adjustable in height to serve practitioners’ needs however, the transfer surface could be fixed within the proposed height...
-
Paragraph (c) Access to moving text (Section-by-Section Analysis)
Paragraph (c) Access to moving text (Section-by-Section Analysis) Comment. The NPRM provision exempted TTYs from this provision because it assumed a person who needed static text...
-
§1193.43(c) Access to moving text
(c) Access to moving text. Provide moving text in at least one static presentation mode at the option of the user.
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
A4.32.4 Height of Tables or Counters
A4.32.4 Height of Tables or Counters. Different types of work require different table or counter heights for comfort and optimal performance....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
A4.32.4 HEIGHT OF WORK SURFACES
Heavy manual work such as rolling dough requires a work surface height about 10 in (255 mm) below elbow height for a standing person....
-
19 Inch Low Height
Figure 2: Illustration of the height difference between a fixed height and adjustable height medical table Implications of a 19 Inch Minimum Standard for the Highest Point in the Lowest...
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal....
-
18 Inch Low Height
18 Inch Low Height As our discussions progressed on the low height, whether it should be 17 inches, 18 inches or 19 inches; a compromise position of 18 inches was suggested....
-
Alarms: ADA Standard Section 807.3.1
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided. EXCEPTION: Visible alarms shall not be...
-
Activation: ADA Standard Section 809.5.1.2
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the...
-
Alarm Appliances: ADA Standard Section 809.5.1.1
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702.
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3. [2010 ADA...
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided. Exception: Visible alarms...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the...
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3. [2010 ADA...
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided. Exception: Visible alarms...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the...
-
Common Problems with Signs
Common Problems with Signs Ø Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to...
-
Re: 11B-216.6 Entrances
11B-216.6 Entrances. In existing buildings and facilities where not all entrances comply with Section 11B-404, entrances complying with Section 11B-404 shall be identified by the...
-
17 Inch Low Height
17 Inch Low Height A portion of the Committee maintained that a height range of 17 inches - 25 inches would accommodate a significant portion of people with disabilities....