Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
Search Results "Alternate Door"
Commonly Searched Documents
-
1132A.6 Closer-effort to operate doors
- Retail Store Disability Access; Dawn Secret Treasures: BigBell
-
F206.5.1 Entrances
Each entrance to a building or facility required to comply with F206.4 shall have at least one door, doorway, or gate complying with 404....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
- ADAEZ Pro Plus Automatic Door Opener Installing Door Arm Pivot Video
-
F206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
F206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
§ 38.157(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
Check-In and Check-Out Procedures
Instead, you should inform the guest what services – including alternate format materials such as Braille, large print, and audio cassette versions of printed material normally provided...
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
Can handrails overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
H. Door Maneuvering Clearance
On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Spacing the Door Arm Video
-
4.13.11(1)
(1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....