Under the "program accessibility" requirement in title II, each service, program, or activity, when viewed in its entirety, must be readily accessible to and usable by individuals with disabilities...
Search Results "Limited Access Space"
-
Section 35.150(b)(2) Safe Harbor (Section-by-Section Analysis)
-
I. The Disabilities Convention and U.S. Disability Rights Law
Each requirement is tempered by limitations that reflect the difficulty and costs of achieving accessibility....
-
Where Required: Multi-Story Buildings and Facilities [§206.2.3]
Where Required: Multi-Story Buildings and Facilities [§206.2.3] An accessible route must connect each story and mezzanine in a facility unless an exception applies....
-
§ 35.151(f)(2)
(2) Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in accordance with section 809.2 of the 2010...
-
First Victory
The administration also considered introducing legislation limiting the level of service for, and individual attention to, persons with disabilities in the educational process.49 Prior...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables. At both ends of adult changing tables, clearance...
-
6.9 Tread Obstacles
Obstacles on beach access routes and their related resting intervals shall not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
4.1.6(1)(f)
(f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible vertical...
-
Fire Rings, Grills, Fireplaces, and Wood Stoves
If the grill doesn't rotate, clear space is only required on the sides from which access is needed to use the grill. Most fire rings are also usable on all sides....
-
Subpart F—Certification of State Laws or Local Building Codes (Section-by-Section Analysis)
provides that on the application of a State or local jurisdiction, the Attorney General may certify that a State or local building code or similar ordinance meets or exceeds the minimum accessibility...
-
§ 36.501(b) Injunctive relief
violations of § 36.304, §§ 36.308, 36.310(b), 36.401, 36.402, 36.403, and 36.405 of this part, injunctive relief shall include an order to alter facilities to make such facilities readily accessible...
-
§ 35.151(b)(4)(ii)(A)
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
§ 35.151(b)(4)(ii)(A)
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
F213.1 General
Where toilet facilities and bathing facilities are provided in facilities permitted by F206.2.3 Exceptions 1 and 2 not to connect stories by an accessible route, toilet facilities and bathing...