Requirements for route and destination signs are subject to specifications for visual signs in section 703, including character height (810.6.2)....
Search Results "Local Requirement"
Commonly Searched Documents
-
Route and Destination Signs
-
Gates
In addition, clarification has been added that the requirements for manual doors, doorways, and gates in section 404.2 apply to those "intended for user passage." Comment....
-
IX. New Construction
The new construction requirements apply to any facility occupied after January 26, 1993, for which the last application for a building permit or permit extension is certified as complete...
-
241 and 612 Saunas and Steam Rooms
241 and 612 Saunas and Steam Rooms Section 241 of the 2010 Standards sets scoping for saunas and steam rooms and section 612 sets technical requirements including providing accessible...
-
Noncomplying new construction and alterations
Section 36.406(a)(5) of the final rule sets forth the rules for noncompliant new construction or alterations in facilities that were subject to the requirements of this part....
-
214 and 611 Washing Machines and Clothes Dryers
214 and 611 Washing Machines and Clothes Dryers Sections 214.2 (washing machines) and 214.3 (clothes dryers) of the 2010 Standards specify the number of each type of these machines required...
-
§ 382.37 Seat assignments
(a) Carriers shall not exclude any qualified individual with a disability from any seat in an exit row or other location or require that a qualified individual with a disability sit in any...
-
4. Pressure Gauge
Many people with disabilities have limitations on the amount of force they can exert to open a door or operate a device that requires pushing or pulling....
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (...
-
Noncomplying new construction and alterations
Section 35.151(c)(5) of the final rule sets forth the rules for noncompliant new construction or alterations in facilities that were subject to the requirements of this part....
-
Number of Assistive Listening Systems
Facility operators urged the Board to lower the required number of receivers because, in their view, the vast majority of provided receivers go unused....
-
Unisex Toilet Rooms
Comments advised revising requirements for unisex toilet and bathing rooms for greater consistency with model building codes....
-
F221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by F221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
F221.2.3 Lines of Sight and Dispersion
When the number of wheelchair spaces required by F221.2.1 has been met, further dispersion shall not be required....
-
1133B.5.4.5
At bottom and intermediate landings, the width shall be at least the same as required for the ramps. 1133B.5.4.6 Change of direction. ...
-
1003.2.13.2 Enclosed exit stairways
The clear width of 48 inches (1219 mm) between handrails and the area of refuge is not required at exit stairways in buildings or facilities equipped throughout with an automatic sprinkler...
-
Visual Devices for the Fire Alarm System
Many codes require new buildings to have flashing strobe lights (visual devices) as part of the standard building alarm system, but because the requirements are not retroactive many buildings...
-
Many properties do NOT have enough electricity available to support significant charging installations, so for now, utilities and others are doing “make ready” spaces (upgrading the supporting infrastructure in a parking space for future use without adding the actual charger). How would make ready spaces comply with the ADA standards? Additionally, consider a site with 10 make ready spaces. Would the standards apply differently if that site has no chargers presently installed versus having one active charger installed?
It would be prudent for a designer to take into consideration the space requirements necessary for accessible EVCS based on the total projected number of EVCS planned for the site, in addition...
-
§27.19(a)
(a) Recipients subject to this part (whether public or private entities as defined in 49 CFR part 37) shall comply with all applicable requirements of the Americans with Disabilities Act...
-
Implementation Challenges for Interiors (slides 16 and 17)
Prescriptive requirements are great, [if they are] backed by research, but that also may limit the design creativity and options and force someone to design something somewhere that may...
-
2. Section-by-Section Analysis of Final Guidelines
Section 3 reprints the text of 24 CFR 100.205, which implements the Fair Housing Act's accessibility requirements, and Section 4 describes the application of the Guidelines....
-
604.8.1.4 Toe Clearance
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted...
-
221.2.3 Lines of Sight and Dispersion
When the number of wheelchair spaces required by 221.2.1 has been met, further dispersion shall not be required....
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
Section 36.406(a)(5) of the final rule sets forth the rules for noncompliant new construction or alterations in facilities that were subject to the requirements of this part....