Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
Search Results "Lavatory Clear Floor Space"
-
R210 Protruding Objects
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
Getting From Here to There—Outdoor Recreation Access Routes
Design outdoor recreation access routes to meet technical requirements for running and cross slopes, resting intervals, surface, clear tread width, passing spaces, tread obstacles, protruding...
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
Re: § 36.403(d) Landlord/tenant
Tenant space alterations may trigger path of travel obligations for the landlord....
-
Overhead Lifts
Overhead lifts and portable floor lifts are used in health care facilities, and the technical criteria should not be viewed as preferring portable floor lifts....
-
Re: Tax Information for People with Disabilities A Complete and Simple Guide
Examiners look for clear judgement, well-defined criteria, strong evidence, and critical analysis....
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests. ...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests....
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....