Armrests are not required, however if provided, the armrest opposite the water must be removable or be able to fold clear of the seat when the seat is in the raised (load) position....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
Footrests and Armrests
-
R406 Reach Ranges (Section-by-Section Analysis)
ABA Accessibility Guidelines in that forward reach over an obstruction is not permitted, and side reach over an obstruction is permitted where the depth of the obstruction between the clear...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail. [2010 ADAS] 505.5 Clearance. ...
-
Protruding Object
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit overhangs of natural protruding objects....
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the recreation access route....
-
Protruding Object
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit overhangs of natural protruding objects....
-
Parking sign height measurement technique
502.6 says "Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign." But which floor or ground surface? ...
-
Health Care Providers
The guidance document includes information on accessible examination rooms and the clear floor space needed adjacent to medical equipment for individuals who use mobility devices to approach...
-
Health Care Providers
The guidance document includes information on accessible examination rooms and the clear floor space needed adjacent to medical equipment for individuals who use mobility devices to approach...
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
E. Tray Slides
If cafeteria style food service lines are provided, are the tray slides no higher than 34" above the floor and queue lines at least 36" wide (42" minimum if u-turns are required) along the...
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
407.12.2.1 Unobstructed Side Reach
part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
Flush Controls [4.18.4]
Flush Controls [4.18.4] Flush controls must be mounted no more than 44 inches above the finished floor and must: be automatic or operable by one hand operate without...
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....