Search Results "Vertical Access"
- Figure 1009.2.8 Pool Lift Submerged Depth – Drawing from the U.S. Access Board
- Figure 1009.2.2 Pool Lift Seat Location – Drawing from the U.S. Access Board
- Figure 1009.3.2 Sloped Entry Submerged Depth – Drawing from the U.S. Access Board
- Figure 304.3.2 T-Shaped Turning Space – Drawing from the U.S. Access Board
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Figure 1009.2.4 Pool Lift Seat Height – Drawing from the U.S. Access Board
- Figure 705.1 Size and Spacing of Truncated Domes – Drawing from the U.S. Access Board
- Figure 1009.4.3 Depth and Length of Tranfer Walls – Drawing from the U.S. Access Board
- Figure 1009.4.5 Grab Bars for Transfer Walls – Drawing from the U.S. Access Board
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....
-
Handrail Extensions
Other specifications regarding vertical supports may be addressed in other building codes....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
Transfer Height
If multiple transfers are necessary to reach the amusement ride seat, it is recommended that each vertical transfer not exceed 8 inches....
-
Handrails
[ADA Stds. 4.9] Yes __ No __ N/A __ Comments: ___________________________________________ ...are the handrails continuously grippable, without interruption by vertical supports, newel...
-
4.4.3 Backrest and Armrest
structural strength of backs, armrests, and mounting devices shall comply with section 903.6 of the ABAAS, which states: “Allowable stresses shall not be exceeded for materials used when a vertical...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
407.2.2.2 Visible Signals
The visible signal elements shall be 2½ inches (64 mm) minimum measured along the vertical centerline of the element....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...