Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
-
609.4 Position of Grab Bars
-
Sec.36.401(d)(1)(ii)(B)
The facility housing a "shopping center or shopping mall'' only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use...
-
When alterations are made on an upper story of a facility, is vertical access required?
If alterations are made to a primary function area on an upper floor, an accessible path of travel to the area is required to the extent that the cost is not disproportionate (i.e., more...
-
Car Position Indicators [§407.4.8]
Specifications include: ½” min. character height Illumination of each floor level passed or stopped at Automatic verbal announcement of stop or non-verbal audible...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Section 35.151(f) Housing at a place of education (Section-by-Section Analysis)
There are other differences between the two sets of standards as well with respect to requirements for accessible windows, alterations, kitchens, accessible route throughout a unit, and clear...
- AJW Architectural Products U701 Series Frameless Mirror
- HEWI System 100 Door Hardware
- HEWI Range 260 Door Hardware
-
Problem Five
Problem Five: A large number of accessible parking spaces are provided, including van accessible spaces, at a school near the main building entrance....
- Texas Department of Licensing and Regulation (TDLR)
-
M301.4.2 Clearance Around Base (Section-by-Section Analysis)
The MDE NPRM proposed certain requirements to provide clearance around the base of the diagnostic equipment to allow the legs of the portable floor lift to straddle the base of the diagnostic...
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
e-i
Are the centerlines of the call buttons mounted 42 inches above the floor? [ADA Standards § 4.10.3] Yes No...
-
H19
Is the top of the toilet seat 17 inches to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No...
-
Section 2. Loft
"Loft" means an intermediate level between the floor and ceiling of any story, located within a room or rooms of a dwelling....
-
4.18.2 HEIGHT
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....