seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
Search Results "Centered Clear Floor Space"
Commonly Searched Documents
-
11B-608.5.2 Standard roll-in type shower compartments
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
- Center for Independent Living of North Central Florida - Gainesville, Ocala, FL
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
Spy City Café
bottom edges of the reflecting surfaces of the mirrors in the men's and women's toilet rooms located outside the Café and designated as accessible are mounted 57 ½" [sic] from the finished floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
- Rehabilitation Engineering Research Center (RERC) on Hearing Enhancement
-
A1. Parking Count
Are the minimum number of accessible parking spaces provided, based on the total number of available parking spaces (see table below)?...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
R210 Protruding Objects (Section-by-Section Analysis)
Objects also must not reduce the clear width required for pedestrian access routes....
- Options Interstate Resource Center for Independent Living - East Grand Forks, MN
-
4.2 Stretchers
With these essential features competing for the same vertical space, current stretchers cannot lower to the desired minimum height of 17" to 19" (see Sections 5 and 6)....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
11B-810.1.2 Baggage systems
Baggage check-in and retrieval systems shall be on an accessible route complying with Section 11B-402 and shall have space immediately adjacent complying with Section 11B-302....
-
New Accessible Handpump for Campgrounds
The Missoula Technology and Development Center (MTDC) conducted an indepth market search and found no hand-operated water pumps meeting the Americans With Disabilities Act (ADA) standards...