(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
§ 36.403(c)(1)(ii)
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
-
4.7.9.4 Depth
The bottom of the bowl shall be at least 15 inches (380 mm) above the floor or ground....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
10 - foot straightedge method
10 - foot straightedge method This is the classic method for determining the flatness of concrete and other types of finished floors....
-
Problem One
Problem One: Parking is available, but no accessible parking is provided or there are not enough accessible parking or van accessible spaces....
-
Problem One
Problem One: Parking is available, but no accessible parking is provided or there are not enough accessible parking or van-accessible spaces....
-
1 - Design and drawing
Tolerances do not apply where a requirement states a range; for example, that grab bars must be installed between 33 inches and 36 inches above the finished floor....
- Design for All Foundation
- ALUMAT Magnetic Doors Seals for External Doors
-
Public Way
other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear...
-
707.3 Operable Parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
106.5.51 Public Way
other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear...
-
707.3 Operable Parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
Paperwork Reduction Act
., requires agencies to clear forms and record keeping requirements with OMB before they can be introduced. ...
-
Paperwork Reduction Act
The Paperwork Reduction Act of 1980 (PRA) requires agencies to clear forms and record keeping requirements with OMB before they can be introduced. 44 U.S.C. 3501 et seq....
-
ASSISTIVE LISTENING SYSTEM (ALS)
[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop,...
-
11B-502.8 Additional signs
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...