1132A.7 Type of lock or latch. The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
Search Results "Single-Story Dwelling Unit (FHA)"
Commonly Searched Documents
-
1132A.7 Type of lock or latch
-
1133A.5 Lower shelving
1133A.5 Lower shelving. Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
4.34.2(14)
(14) If laundry facilities are provided, they shall comply with 4.34.7.
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use. Clear spaces at least 30 in (760 mm) wide under counters at the side of ovens...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
Transient Lodging
A building, facility, or portion thereof, excluding inpatient medical care facilities, that contains one or more dwelling units or sleeping accommodations....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor...
-
4.34.2(15)
(c) The sleeping area, or the bedroom in one bedroom dwelling units, or at least two bedrooms or sleeping spaces in dwelling units with two or more bedrooms....
-
203.8 Residential Facilities, F203.9 Residential Facilities
203.8 Residential Facilities F203.9 Residential Facilities These sections contain a general exception for facilities with residential dwelling units....
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
Alterations—28 CFR 35.151
In certain situations, application of the 2010 Standards may result in fewer units containing accessibility features....