(4) Ramp barriers. Each side of the ramp shall have barriers at least 2 inches (50 mm) high to prevent mobility aid wheels from slipping off....
Search Results "Ramp Landing"
Commonly Searched Documents
-
§ 38.159(c)(4) Ramp barriers
-
§ 38.83(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
11B-206.2.19 Pedestrian street crossings
Where walks or sidewalks are provided, a curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with Section 11B-406 shall connect the walks or sidewalks...
- SafePath: Threshold Ramp Installation for MultiFamily Housing for Disability Access
-
§ 38.125(c)(5) Slope
Ramps or bridge plates shall have the least slope practicable....
-
4.7.10 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
T402.12 Stowage
Where portable ramps and bridgeplates are permitted, a compartment, securement system, or other storage method shall be provided within the non-rail vehicle to stow such ramps and bridgeplates...
- Figure 505.10.1 Top and Bottom Handrail Extension at Ramps – Drawing from the U.S. Access Board
-
4.7.10 DIAGONAL CURB RAMPS
If diagonal (or corner type) curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow....
-
§ 38.23(c)(3) Ramp threshold
(3) Ramp threshold. The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch....
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2....
-
§ 38.159(c)(6) Attachment
When in use for boarding or alighting, the ramp shall be firmly attached to the vehicle so that it is not subject to displacement when loading or unloading a heavy power mobility aid and...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1. ...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1....
-
4.7.8 Obstructions
Curb ramps shall be located or protected to prevent their obstruction by parked vehicles....
-
4.7.8 OBSTRUCTIONS
Curb ramps shall be located or protected to prevent their obstruction by parked vehicles....
-
4.7.3 Width
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
-
4.7.3 WIDTH
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches....
-
City of Bend Oregon Curb Ramp Commitment
Requires the Registered User plan or above. Login!
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
4.10.4(3)
(3) Signals shall be visible from the vicinity of the hall call button (see Fig. 20). In-car lanterns located in cars, visible from the vicinity of hall call buttons, and conforming...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...