Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
Search Results "Pull Side"
Commonly Searched Documents
-
11B-308.3.2 Obstructed high reach
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door. In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
5.4.1.1 Transfer Support Location for Stretchers
The transfer surface for stretchers should be oriented along the long side of the surface....
-
A. Passenger Drop-Off Areas
A. Passenger Drop-Off Areas During an evacuation the most efficient method of transporting people to shelters likely will include using vans and buses. Accessible buses and vans...
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
Here's a good example of one solution for a water closet that's too far from the adjacent side wall. ...
- Rockwood Manufacturing Company 596 Hospital Push Pull Latch 5" Backset
-
5.2.1.3 Transfer Surface Size for Stretchers
The transfer surface should be 28 inches wide minimum and 17 inches deep minimum located on both long sides of stretchers....
-
4.1.1 Range of Examination Table and Chair Configurations
Equipment designed for patients in prone or side-lying positions (M301) Examination tables Podiatry tables 2....
- TelCom Wheelock Fire Alarm Pull Station MPS-100
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- 308.3.1 Automatic Trash Can Height
- Universal Industrial Products SOSS UltraLatch
-
Reach Ranges and Operability Requirements
Design Tip Understand forward reach and side reach terminology....
-
Re: 404.2.4.3 Recessed Doors and Gates
A barrier within 18" of the latch side of a push approach door will trigger the extra requirements....
-
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position....
- Rockwood Manufacturing Company 596S Hospital Push Pull Latch 2-3/4" Backset
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M301.3.1 and M302.3.1 would require transfer supports to be provided for use with the transfer sides....
-
Section D: Entrances
(§§309.4, 404.2.7) D3 On the pull side of the door, is there at least 18" of clearance provided to the side of the latch?...