Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
Search Results "Picnic Table"
-
M305.2.4.2 Non-Circular Cross Section
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.
-
804.3 Kitchen Work Surface (Exception)
The exception does not require work surfaces to be provided at kitchen counters where a table is provided within the kitchen; an electric outlet is provided within reach of the table; and...
-
5 “G’s” Getting Access to Health Care for People with Physical Disabilities
By June Isaacson Kailes, Associate Director Center for Disability Issues and the Health Professions Western University of Health Sciences jik@pacbell.net 2008...
-
Conditions for Exceptions [1019]
Table 1 summarizes the conditions for exceptions and when and where they may apply....
-
3.5.2 Color of the ISA
Per section 703.7 of the ABAAS, the ISA shall be posted in high-contrast colors. The ISA is not required to be blue and white when posted on Federal lands.
-
Accessible Medical Equipment
For participants with mobility limitations, we use exam and procedural tables and chairs that: [See Resources below and Section H] D.1....
-
2.1 General
ORARs shall be provided between units and constructed features in campgrounds, picnic areas, trailheads, viewing areas, and other outdoor recreation sites....
- Kompan, Inc. ELE400205 - Cottage Playhouse
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
- Defining and Delivering Disability-Competent Care - The Lived Experience Of Disability
-
California Department of Managed Health Care - Physical Access to Health Care Fact Sheet
If You Use a Wheelchair or Have a Hard Time Walking
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]
-
M302.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A. A low transfer position...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum. The Access Board...
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
As discussed in Section IV.B.1.a. (Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a...
-
Table 1