(New rule section effective March 1, 2007, 32 TexReg 884) When preliminary construction documents are mailed, shipped or hand-delivered with an Architectural Barriers Special Registration...
Search Results "Outdoor Constructed Feature"
Commonly Searched Documents
-
68.55. Preliminary Plan Reviews
-
11B-246.2 Camping facilities
In camping facilities where campsites are provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected...
-
6. Regulatory Analyses
[See subsections ...]
-
Trash Receptacles and Wildlife
Safety is also the primary issue when it comes to the accessibility of trash receptacles. In bear country, use trash and recycling containers designed to keep the bears out to...
-
R212.6 Benches
R212.6 Benches. At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench. The clear space shall be...
-
903.4 Back Support
The bench shall provide for back support or shall be affixed to a wall. Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum...
-
4.4.2 Height
The front edge of the seat of a bench shall be at least 17 inches (430 mm) and no more than 19 inches (485 mm) above the floor or ground.
-
11B-246.2 Camping facilities
In camping facilities where campsites are provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected...
-
11B-246.2 Camping facilities
In camping facilities where campsites are provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected...
-
Designed and Constructed for First Occupancy (Section-By-Section Analysis and Response to Comments)
Designed and Constructed for First Occupancy (Section-By-Section Analysis and Response to Comments) According to paragraph (a)(2), a facility is subject to the new construction requirements...
-
Triggering event. (Section-by-Section Analysis)
In § 35.151(c)(2) of the NPRM, the Department proposed that the commencement of construction serve as the triggering event for applying the proposed standards to new construction and alterations...
-
Cross Slope [1016.7.2]
When the surface is constructed of concrete, asphalt, or boards, the cross slope must be no steeper than 1:48 (2 percent)....
-
806.1 General
Guest rooms required to provide mobility features shall comply with 806.2. Guest rooms required to provide communication features shall comply with 806.3....
-
806.1 General
Guest rooms required to provide mobility features shall comply with 806.2. Guest rooms required to provide communication features shall comply with 806.3....
-
4. Access to Newly Constructed and Altered Facilities
Access to Newly Constructed and Altered Facilities In implementing the program, the City will ensure that all future construction and alteration work on Pedestrian Facilities will be...
-
Sec.36.401 New construction
Sec.36.401 New construction....
-
11B-806.1 General
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. Guest rooms required to provide communication features shall comply with Section 11B-806.3....
-
11B-806.1 General
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. Guest rooms required to provide communication features shall comply with Section 11B-806.3....
-
11B-806.1 General
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. Guest rooms required to provide communication features shall comply with Section 11B-806.3....
-
Section 201.1
Section 201.1 The basic scoping requirement requires all areas of newly designed and newly constructed buildings and facilities to be accessible....
-
Benches [1011.2]
technical requirements in section 903 of the ABA Standards apply only to benches used for dressing and undressing in fitting and locker rooms, and not to benches used for sitting in an outdoor...
-
806.1 General
Guest rooms required to provide mobility features shall comply with 806.2. Guest rooms required to provide communication features shall comply with 806.3....
-
1016.5 Obstacles
Natural features such as tree roots and rocks on outdoor recreation access routes can also be obstacles. ...
-
1016.5 Obstacles
Obstacles on outdoor recreation access routes, passing spaces, and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....