Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with 1008.4. Advisory F240.2.2 Elevated Play Components....
Search Results "Non-Elevator Building"
Commonly Searched Documents
-
F240.2.2 Elevated Play Components
-
240.2.2 Elevated Play Components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with 1008.4. Advisory 240.2.2 Elevated Play Components....
-
Toilet and Bathing Facilities [F213 and 603 through 610]
When toilet and bathing facilities are provided, they must comply with the scoping and technical requirements in sections F213 and 603 through 610 of the ABA Standards. When...
-
§ 36.601 Model Code
Model code means a nationally recognized document developed by a private entity for use by State or local jurisdictions in developing codes as defined in this section. A model code...
-
Qualified Historic Facility
Qualified Historic Facility. A facility that is listed in or eligible for listing in the National Register of Historic Places, or designated as historic under an appropriate state or...
-
4.2 Immediately Preceding Edition
4.2 Immediately Preceding Edition: The immediately preceding edition of the code includes: • The initially adopted and published code; • Intervening Code Cycle Amendments...
- Patriot Portable Lift by Aqua Creek Products
-
Requirement 7 -- Usable Kitchens and Bathrooms
[See subsections ...]
-
233.3.4.1 Alterations to Vacated Buildings
233.3.4.1 Alterations to Vacated Buildings....
-
Conflict with Local Accessibility Codes
The commenter pointed out that the State of Washington is very hilly, and that the State of Washington's accessibility code requires accessible buildings on sites that would be deemed impractical...
-
Exception 9
In alteration projects involving buildings and facilities previously approved and built without elevators, areas above and below the ground floor are subject to the 20-percent disproportionality...
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
1008.2.4.2 Elevated
1008.2.4.2 Elevated. The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
Plumbed Fixtures
Where non-fixed units are provided instead, consideration should be given to their usability by people who use wheelchairs and those who may have difficulty bending or stooping....
-
1150A.1 General
Covered multifamily dwellings in buildings without an elevator, located on sites with difficult terrain conditions or unusual characteristics, may employ the site impracticality tests in...
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
11B-407.2.1.6 Keypads
ETA Editor's Note Lacking certain Exceptions allowed by 2010 ADA Standards, and imposing additional requirements regarding call buttons, the preceding CBC requirements pertaining to elevator...
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
[2010 ADAS] 105.2.4 ICC/IBC
International Building Code, 2000 Edition (see 207.1, 207.2, 216.4.2, 216.4.3, and 1005.2.1). International Building Code, 2001 Supplement (see 207.1 and 207.2)....
-
ICC/IBC
International Building Code, 2000 Edition (see 207.1, 207.2, 216.4.2, 216.4.3, and 1005.2.1). International Building Code, 2001 Supplement (see 207.1 and 207.2)....
-
2013 California Standards for Accessible Design
2013 California Standards for Accessible Design Pocket Guide
-
2016 California Standards for Accessible Design
[See subsections ...]