At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
Search Results "Handrail Diameter"
-
11B-1005.4 Clear floor or ground space
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
Attachment J
Provide handrails that are between 1¼ inches and 1½ inches in diameter with a continuous gripping surface along both sides of the ramp, extending at least 12 inches beyond the top and bottom...
-
Keypads: ADA Standard Section 407.4.7.2
Section 407.4.7.2 covers the current ADA Standards for designations and indicators on elevator keypads.
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
Clear Width: ADA Standard Section 405.5
Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
1012.3 Opening limitations
Open guards shall have balusters or ornamental patterns such that a 4-inch-diameter (102 mm) sphere cannot pass through any opening up to a height of 34 inches (864 mm)....
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities....
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities....
-
1003.2.12.2 Opening limitations
Open guards shall have balusters or ornamental patterns such that a 4-inch-diameter (102 mm) sphere cannot pass through any opening up to a height of 34 inches (864 mm)....
-
Re: 1100KG BT Digital Platform Scale Extra Wide Handrails and Built-in Pelstar® Wireless Technology
-
Re: Stair widths
The reason for the 48 inch requirement between handrails here is because people with mobility issues may require assistance down or up the stairs. ...
-
Accessible Routes: ADA Standard Section 1007.2
Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with 505....
-
11B-405.7.2.1
Handrail extensions are not permitted to obstruct required clear landing dimensions except as allowed by the exception to Section 11B-307.2....
-
11B-405.7.2.1
Handrail extensions are not permitted to obstruct required clear landing dimensions except as allowed by the exception to Section 11B-307.2....
-
Truncated Domes
The proposed rule specified that the truncated domes have a diameter of 0.9 inch, measured at the base....
-
Can stair treads and risers be perforated?
Stair treads must meet requirements for floor or ground surfaces which specify that surface openings not allow passage of a sphere more than ½ inch in diameter (§302.3)....
-
Edge Protection [4.8.7]
Handrails alone do not necessarily provide effective edge protection for people who use wheelchairs, crutches, and other mobility aids....
-
11B-1007.2 Accessible routes
Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with Section 11B-505. ...
-
11B-1007.2 Accessible routes
Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with Section 11B-505. ...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...