408.3.2.1 Power Operation. Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced...
Search Results "Elevator Car Identification"
Commonly Searched Documents
-
408.3.2.1 Power Operation
-
408.3.2.2 Duration
408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-411.4.5 Illumination
The level of illumination at the car controls shall comply with Section 11B-407.4.5....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
Accessible golf cars (Section-by-Section Analysis)
Accessible golf cars....
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
- Figure 407.2.2.2 Visible Hall Signals – Drawing from the U.S. Access Board
-
Elevators: ADA Standard Section 216.7
Section 216.7 covers scoping requirements in the current ADA Standards for signs at elevators.
-
Private Residence Elevators: ADA Standard Section 409
Section 409 covers the current ADA Standards for private residence elevators.
-
11B-502.6.4.2
ETA Editor's Note The CBC identification requirements for accessible parking spaces and van accessible parking spaces are more extensive than those in 2010 ADA Standards....
- Savaria Orion LU/LA Elevator Video
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
407 Elevators
Section 407 covers passenger elevators, including destination-oriented elevators and existing elevators....
-
Alternative Golf Car Passage
A golf car passage is a continuous passage on which a motorized golf car can operate....
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....