407.3 Tactilely Discernible (Section-by-Section Analysis) This section proposes to require that at least one tactilely discernible input control conforming to the requirements of this...
Search Results "Control End Wall"
-
407.3 Tactilely Discernible (Section-by-Section Analysis)
-
Swimming Pools: ADA Standard Section 242.2
Section 242.2 covers scoping requirements in the current ADA Standards for swimming pools.
-
11B-242.2 Swimming pools
Accessible means of entry shall be swimming pool lifts complying with Section 11B-1009.2; sloped entries complying with Section 11B-1009.3; transfer walls complying with Section 11B-1009.4...
-
11B-242.2 Swimming pools
Accessible means of entry shall be swimming pool lifts complying with Section 11B-1009.2; sloped entries complying with Section 11B-1009.3; transfer walls complying with Section 11B-1009.4...
-
407.6 Operation
At least one mode of operation shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts...
-
407.9 Operation (Section-by-Section Analysis)
407.9 Operation (Section-by-Section Analysis) This section would require ICT with operable parts to provide at least one mode of operation that is operable with one hand, and...
-
407.9 Operation
At least one mode of operation shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts...
-
Must operable parts be usable with a closed fist?
Closed-fist operation is a good performance test but is not required by the standards. Many types of operable parts, such as pull handles, satisfy the requirements even though they...
- Symmons Temptrol II (2000 Series) Tub/Shower Mixing Valve 15-2
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
Elevators
reopening devices (§ 4.10.6); Door and signal timing for hall calls (§ 4.10.7); Door delay for car calls (§ 4.10.8); Illumination levels (§ 4.10.11); Car control...
-
6.14.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7....
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
707.6.1 Input Controls
At least one tactilely discernible input control shall be provided for each function....
-
707.6.1 Input Controls
At least one tactilely discernible input control shall be provided for each function....
-
1011.3 Operable Parts
Exception 2 requires trash and recycling receptacles with hinged lids and controls to keep out large animals to comply with the technical requirements for operation in 309.4 of the Architectural...
-
11B-604.5.2 Rear wall
11B-604.5.2 Rear wall....
- Figure 703.7.2.3 Volume Control Telephone – Drawing from the U.S. Access Board
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
403.1 General
Where provided, biometrics shall not be the only means for user identification or control....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....