Rigid plastic lavatory enclosure 20" by 18" Conceals all piping, heaters, and other equipment below sink. 3-year warranty
Search Results "Clearance"
Commonly Searched Documents
- Zurn Industries Rigid Lavatory Enclosure - Vandal Gard
- McGuire Manufacturing Co., Inc. 155WC: Offset Lavatory Strainer
- McGuire Manufacturing Co., Inc. ProDrainWC: Lavatory Strainer Less Overflow
- McGuire Manufacturing Co., Inc. 1151WC: Offset Strainer with 151 Basket Strainer
- IPS Corporation Truebro® Lav Shield® Protective Lavatory Enclosure
- McGuire Manufacturing Co., Inc. PW1000WC: 1 1/2" Offset Sink
- McGuire Manufacturing Co., Inc. 1000WC: Offset Strainer - Offset Only
- McGuire Manufacturing Co., Inc. 1152WC: Offset with 152 Wide Top Strainer
- McGuire Manufacturing Co., Inc. Heavy Finish Offset Lavatory Strainer
-
Voting Area
Within the voting area there must be enough clearance for an individual with a disability to access and use all the voting equipment....
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
4.17.5* DOORS
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm)....
-
4.17.5* Doors
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm) (Fig. 30...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
1132A.4 Level floor or landing
1132A.4 Level floor or landing. See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors...
-
8. Gap
8. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
11. Gap
11. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
H. Drop-off Area Height
H. Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area? [ADA Stds. 4.6.5] Yes __ No __ N/A __ Comments:...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
4.3.5 HEAD ROOM
Accessible routes shall comply with 4.4.2.